ALT
−0004 M
SLAB

Technical installations / Imaging environments

From slab to scan.

Imaging environments are one application of our technical project delivery work. We coordinate room conditions, specialist trades, equipment requirements, and testing through handover.

SECTION A–A · MRI SUITE DWG 01 · NOT TO SCALE → ALT 400 KM HVAC 5 G LINE LHe · 4.2 K B₀ 1.5T / 3T ZONE IV CTRL ZONE III 01020304050607
  1. 01RF shield · Faraday cage
  2. 02Superconducting magnet
  3. 03Quench vent to roof
  4. 04Magnetic shielding · steel
  5. 05Penetration panel · waveguides
  6. 06RF window · control room
  7. 07Slab · loading & vibration
  8. - -5-gauss line
ALT
0000 M
SUITE

01 — What we install · Alt 0 m

Rooms for the most demanding machines in medicine.

MRI, CT, and radiology suites designed, shielded, and installed by one team — from the empty room to the first scan.

MR01 / 06

MRI

  • 1.5T & 3T suites
  • RF enclosure & magnetic shielding
  • Quench vent, cryogen & chilled water
CT02 / 06

Computed tomography

  • Lead shielding to physicist's report
  • Floor loading & anchoring
  • Power, HVAC & data
PT03 / 06

PET/CT

  • Heavy shielding for 511 keV photons
  • Uptake room & hot-lab adjacency
  • Combined CT room requirements
DX04 / 06

Digital X-ray

  • Lead-lined walls, doors & glass
  • Ceiling tube-support structure
  • Control alcove layout
RF05 / 06

Fluoroscopy

  • Shielded procedure rooms
  • Table & C-arm structural support
  • Staff-exposure-aware layout
MG06 / 06

Mammography

  • Compact shielded rooms
  • Tight-footprint planning
  • Patient privacy & workflow

Codes shown are DICOM modality identifiers.

ALT
0060 M
VENT STACK

02 — From empty room to first scan · Alt 60 m

Five phases. Zero guesswork.

Every suite follows the same flight plan, coordinated with the equipment manufacturer's site-planning requirements at every step.

  1. PHASE 01Site surveyStructural, vibration, and EMI surveys. Rigging path from street to room.Load · Vibration · EMI
  2. PHASE 02Room designLayout, 5-gauss line and safety zoning, shielding plan, and MEP coordination.Layout · Zones I–IV · MEP
  3. PHASE 03ShieldingRF enclosure and magnetic shielding for MRI; lead for CT and X-ray, built to the physicist's report.RF · Steel · Lead
  4. PHASE 04Rig & installMagnet delivery, rigging, and set-in-place. Quench vent, power, chilled water, and HVAC.Rigging · Quench · MEP
  5. →
    PHASE 05Test & hand overRF attenuation and radiation surveys, OEM ramp and calibration support, turnover documents.RF test · Survey · Turnover
ALT
0381 M
SKYLINE

03 — Beyond the suite · Alt 381 m

Work that happens while the building stays open.

Hospitals and imaging centers don't pause for construction. Project management and facilities support keep the work moving through the realities of an active site.

FL 03

Execution support

Responsibilities / Sequencing / Decision tracking / Stakeholder alignment

FL 02

Facilities & operations

Improvements / Repairs / Procurement / Ongoing needs in active buildings

FL 01

Project management

Scope / Schedules / Vendor coordination / Budgeting / Documentation / Progress tracking

ALT
0000 M
RETURN

06 — Back on the ground

Start with the room.

Planning a new MRI or CT suite, replacing equipment, or upgrading shielding? Send us the space and the machine — we'll come back with a clear next step.

Direct line 917 995 1976
SERVICE AREANew York City & surrounding areas
MODALITIESMRI · CT · PET/CT · X-ray · Fluoro · Mammo
PROJECT INQUIRYRESPONSE · NEXT STEP
What's the project?